<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-26 03-54-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 71 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 61 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 62 kHz 19040 0,3729
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,8 dBr 3,50 dBr 4,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 3:54, 26.05.2025
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6201, 6203, 6207, 6205
FM Scope Max at: 62 kHz MIN: 10 kHz % above 76 kHz: 0,3729 Acquired: 2025/05/26 3.53.54 Total samples: 19040 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,7 dBr MIN: 0,8 dBr AVE: 3,50 dBr % above 12,2 dBr: 0,0 Last value: 4,2 dBr (2025/05/26 3.53.54) 03.40 03.42 03.44 03.46 03.48 03.50 03.52 0 2 4 Pm [dBr]